Desmond Tutu once said, “there is only one way to eat an elephant: a bite at a time.” And while chances are none of us will ever literally eat an elephant, the words can offer great advice when a task seems too big or overwhelming to tackle.
One of the first criteria when selecting which standing seam metal roofing (SSR) system to use should always be the roof’s slope. Some systems are designed to work at pitches as low as ¼:12 while others require minimum slopes of 3:12. A host of factors affect the recommended minimum slope. As you might expect, the height of the panel leg is a consideration. But more importantly, is the panel engagement method. As a good rule of thumb, mechanically seamed systems perform better in lower slope situations like ½:12, where snap-together type systems perform best at slopes 3:12 and above.
It’s important to note that you can always install a system on a greater slope. But systems shouldn’t be installed on a lower slope than recommended by the manufacturer without manufacturer project review and approval. Exceptions are made given criteria like geographic location and building geometry, but they are rare.
Bottom line: when faced with a roof slope below 3:12, you can automatically remove all rated systems for 3:12 and above from consideration, effectively narrowing the field and making the decision easier.
Bottom line: It’s typically best for buildings with complicated roof plans to use vertical seam style panels since they are much easier to watertight.
Building size also enters into the equation because some systems are designed to allow the panels to be lapped end to end to facilitate longer panel runs, and other panels are not. Vertical leg mechanically seamed systems (like our Maxima) represent an excellent example of a product that can be lapped end to end, where T-style panels (like our 238T) are an example of a system that must be installed in a single piece panel.
However, if you’re leaning towards a T-style panel but face panel lengths longer than what can be factory produced and delivered, don’t despair. Several manufacturers (including McElroy Metal) now can produce “some” of their panel offering on-site with factory quality equipment in lengths up to 250’ long. Hence, it’s always worth a call to check out job site production availability for your desired system before removing a product from consideration.
Bottom line: always consider your approximate panel length and lapability, if necessary, in your system selection.
Bottom line: If you’re dealing with a project with purlins instead of a solid deck, you can remove all the systems from consideration that require a solid deck.
Uplift values can also vary significantly from system to system, so the building’s design criteria should be considered. While the panels that comprise a standing seam metal roof system may look somewhat similar, many different variables affect their performance. Factors like the height of the rib, how they are attached to the deck, clip design and gauge, the width and gauge of the panel, and even if they are mechanically seamed together or snapped all affect how they perform against the wrath of mother nature and ultimately their ability to meet local building codes and other design criteria.
Bottom line: Know your design criteria and consider only systems which meet your criteria. And when unsure, always seek out technical help from an engineer with your preferred manufacturer.
Yet, for a project with multiple rooftop-mounted curbs, system selection becomes much more critical. While trapezoidal style systems might offer the lowest cost, again, they would be an inferior product selection given the large opening at the panel ends and the challenge to make them watertight. Instead, vertical seam systems, like our Maxima or 238T, would be the preferred type of system.
Bottom line: For roofs with multiple/involved penetrations, vertical seam systems are preferred.
Like our 138T/238T, some roofing systems offer single panel replaceability while other vertical leg panels, like our Maxima, do not. The difference is that panels that offer single panel replaceability are butted together, where those that aren’t needed to be hooked and rolled into place during the installation process.
As you can imagine, making a repair, adding a curb, or even adding to a building can be incredibly problematic with interconnected systems.
Bottom line: For buildings where any modifications are anticipated to the roofing system, the best bet is always to consider a system that offers individual panel replaceability. Sure, you will pay a bit more up front but you’ve also effectively removed the risk of tearing off a perfectly good roof to address a problem.
The topic of warranties also bears consideration in the selection process. Most commercial standing seam roof systems (SRS) are coated with a PVDF (or Kynar 500® coating) and consequently include robust finish warranties; however, weather tightness warranties are not automatically incorporated and are not available with every system. Since their availability isn’t guaranteed, If a weather tightness warranty is desired, it should be a definite consideration during the panel selection phase.
Most manufacturers, McElroy included, have pre-established guidelines regarding which of their systems they make available with a weather tightness warranty. The roof slope and panel style are two of the significant criteria considered. Another typically involves whether the system is deemed hydrostatic (watertight) or hydrokinetic (water-shedding).
Bottom line: If your project requires a weather tightness warranty, limit your product selection to systems where one is available. To learn more about weather tightness warranties, read our earlier blog, “Are Weather Tightness Warranties Worth the Money?”
While many people want to start their SSR selection with aesthetics, they should be one of the last considerations. Don’t misunderstand: we agree that a standing seam roof can be a beautiful element to any project! But we’ve also seen many projects doomed from the start due to improper product selection. Consequently, it’s always best to figure out which systems will properly function for the specific project and then dig into the fun topic of aesthetics.
So, what types of things should you consider? Small roof areas tend to benefit from narrower pan widths to help with scale and size, for starters. The various vertical leg options’ height and width can do a great job of minimizing or maximizing shadow lines. Batten style and shape can also play a dominant factor in curb appeal. And the color is, of course, always a fun consideration.
When roofing surfaces are visible, narrower panels are often selected to help mitigate the concern of oil canning. Additionally, several pan “conditions” or profiles within the panel’s pan should be considered to address oil canning. Striations are a widespread pan condition and ordinarily available for no additional cost. While striated panels can tend to look a little busy while holding a sample in your hands, It’s typically tough to tell the difference between a striated panel and a flat panel after installation. The concern of oil canning is significantly reduced, if not entirely removed.
Bottom line: Consider striations and narrow pan widths to address oil-canning concerns.
So how do you choose the best standing seam roof system? Just follow Desmond Tutu’s advice and take one bite (or decision!) at a time. And if that doesn’t work, contact us. We’re always here to help!